Asbestos register
Asbestos register is one of Demiton's published registers for Australian civil construction. The asbestos register work health and safety regulations require. Demiton keeps it current from the systems a contractor already runs and publishes the record's shape as a versioned JSON Schema, so the same question works whichever system produced the record.
Part of Safety in the register catalog.
- Register ID
asbestos_registerUse this name to ask for the register. The API calls it a shelf ID.- Status
- PlannedDefined ahead of the connector that will fill it.
- Data
- OrganisationPrivate to each organisation's own workspace.
- Version
- v1 (1.0.3)Current version.
Standards
This register's contract was designed against these standards and laws. Holding these records does not by itself certify compliance.
- WHS Act and RegulationsModel Work Health and Safety Regulations (asbestos register, review and management plan duties)
- SWA Code of Practice: How to manage and control asbestos in the workplaceSafe Work Australia model Code of Practice: How to manage and control asbestos in the workplace
Connectors
Connected today
Demiton keeps this register current from these systems now.
No system fills this register yet.
On the roadmap
Systems in the planned connector rollout that can fill this register. Partial means the system holds only some of its fields.
None planned yet.
Fields
17 fields: 1 required, 16 optional.
Required
Every record carries these fields.
- workplaceText
The workplace the register covers.
Optional
Present when the source system records them.
- friableTrue or false
Whether the material is friable.
- projectText
The project, when the workplace is a project site.
- locationText
The specific location of the material.
- conditionText
The condition of the material.
- external_idText
The source's own register entry id.
- identified_onDate
When the asbestos was identified or assumed to be present.
- material_typeText
The type of asbestos or asbestos-containing material.
- review_triggerText
Why the last review happened, e.g. asbestos removed or further asbestos found.
- analysis_resultText
The laboratory result confirming whether the material is asbestos.
- management_planText
The asbestos management plan the entry belongs to.
- competent_personText
The competent person who identified the material.
- last_reviewed_onDate
When the register entry was last reviewed.
- inaccessible_areaTrue or false
Whether the location is inaccessible, so presence is assumed.
- past_removal_workText
Removal work already done on the material.
- identification_basisText
Whether the material was identified by analysis or assumed.
- no_asbestos_identifiedTrue or false
Whether this entry states that no asbestos has been identified.
Use this contract
The contract is a standard JSON Schema (draft 2020-12) document, so any JSON Schema validator can check a record against it. Keywords starting with x-demiton- add Demiton's own meaning, such as units and requiredness, and validators ignore them.
https://docs.demiton.io/registers/asbestos_register/v1.jsonShow the full JSON Schema
Loading the schema…
Talk to the team
Tell us what you run - your ERP, field, payroll and document systems - and we will show you the registers Demiton would fill from them, on your data, in a 30-minute call.