Inspection test result
Inspection test result is one of Demiton's published registers for Australian civil construction. Soil and concrete test results (AS 1289, AS 1012). Demiton keeps it current from the systems a contractor already runs and publishes the record's shape as a versioned JSON Schema, so the same question works whichever system produced the record.
Part of Safety in the register catalog.
- Register ID
inspection_test_resultUse this name to ask for the register. The API calls it a shelf ID.- Each record is
- An eventSomething that happened at a point in time.
- Status
- DeclaredDefined, and fills when a source produces its first record.
- Data
- OrganisationPrivate to each organisation's own workspace.
- Version
- v1 (1.0.3)Current version.
Standards
This register's contract was designed against these standards and laws. Holding these records does not by itself certify compliance.
- AS 1012 seriesMethods of testing concrete
- AS 1289 seriesMethods of testing soils for engineering purposes
- AS 1379Specification and supply of concrete
- AS 3798-2007Guidelines on earthworks for commercial and residential developments
- NATA accreditationNational Association of Testing Authorities accreditation
- EN 12350 / EN 12390 / EN 13286European concrete and unbound-mixture test standards
- ISO/IEC 17025:2017General requirements for the competence of testing and calibration laboratories
- NZS 3112:1986Methods of test for concrete
- NZS 4402:1986Methods of testing soils for civil engineering purposes
- BS EN 12350 / BS EN 12390Testing fresh concrete / Testing hardened concrete
- BS EN 13286 / BS 1377Unbound and hydraulically bound mixtures / Methods of test for soils for civil engineering purposes
- ASTM C172 / C31 / C39 / C143 / C231ASTM fresh and hardened concrete sampling and test methods
- ASTM D698 / D1557 / D6938 / D2216ASTM soil compaction, nuclear density and water content methods
Connectors
Connected today
Demiton keeps this register current from these systems now.
No system fills this register yet.
On the roadmap
Systems in the planned connector rollout that can fill this register. Partial means the system holds only some of its fields.
None planned yet.
Fields
28 fields: 6 required, 22 optional.
Required
Every record carries these fields.
- projectText
The project whose works were tested.
Example:
BWG-2025-001- materialText
What was tested, e.g. soil, concrete or aggregate.
Example:
Gravel base course- tested_onDate
The date the test was performed.
Example:
2026-07-22- result_unitText
The unit of the result, e.g. MPa or percent.
Example:
%- test_methodText
The method designation and year, e.g. AS 1012.9:2014.
Example:
AS 1289.5.4.1- result_valueDecimal number
The measured result.
Example:
98.5
Optional
Present when the source system records them.
- outlierTrue or false
Whether the result was treated as an outlier.
- compliesTrue or false
Whether the result meets the specification.
Example:
true- specimenText
The specimen type and geometry, or the mould used.
- test_lotText
The test lot the result belongs to.
- accreditedTrue or false
Whether the laboratory is accredited for the test.
- laboratoryText
The laboratory that did the test.
Example:
Sunstate Geotechnical Testing- sampled_atDate and time
When the sample was taken.
- external_idText
The laboratory report or sample id.
- result_nameText
The quantity measured, e.g. compressive strength or dry density ratio.
- curing_regimeText
How the concrete specimen was cured.
- defects_notedText
Specimen defects recorded at test.
- test_locationText
Where on the works the test or sample was taken.
- field_moistureDecimal number
The field moisture measured.
- mix_identifierText
The concrete mix or supply identifier.
- age_at_test_daysWhole number
The specimen's age when tested.
- competent_personText
The competent person responsible for the test.
- inspection_levelText
The declared inspection and testing level, Level 1 or Level 2.
- field_dry_densityDecimal number
The field dry density measured.
- testing_authorityText
Whether a GITA or a GTA did the testing.
- specification_valueDecimal number
The acceptance criterion the result is judged against.
- reference_dry_densityDecimal number
The reference maximum dry density.
- optimum_moisture_contentDecimal number
The optimum moisture content.
Example record
A sample from Bridgeworks Group, Demiton's demonstration company. The values are illustrative; the shape is exactly what the contract describes.
{ "complies": true, "laboratory": "Sunstate Geotechnical Testing", "material": "Gravel base course", "project": "BWG-2025-001", "result_unit": "%", "result_value": 98.5, "source_system": "SHAREPOINT", "test_method": "AS 1289.5.4.1", "tested_on": "2026-07-22"}Use this contract
The contract is a standard JSON Schema (draft 2020-12) document, so any JSON Schema validator can check a record against it. Keywords starting with x-demiton- add Demiton's own meaning, such as units and requiredness, and validators ignore them.
https://docs.demiton.io/registers/inspection_test_result/v1.jsonShow the full JSON Schema
Loading the schema…
Talk to the team
Tell us what you run - your ERP, field, payroll and document systems - and we will show you the registers Demiton would fill from them, on your data, in a 30-minute call.